HFC blend · R-438A ASHRAE A1 ODP 0 GWP 2,265 Purity ≥99.9%

R438A is the most forgiving R22 retrofit on the market, and that is deliberate. Two hydrocarbons (R600 and R601a) total just 2.3% of the blend but they carry oil back to the compressor well enough that mineral oil, alkylbenzene and POE all work. Pressures sit close to R22 and capacity lands within 5-10%, which is why contractors reach for it when the system history is unknown.

Physical properties

Chemical nameR-438A
CompositionR-32/R-125/R-134a/R-600/R-601a = 8.5/45/44.2/1.7/0.6 (% mass)
Molecular formulaR-32 / R-125 / R-134a / R-600 / R-601a
Molecular weight99.10
Boiling point 101.3KPa(℃)-42.3
Freezing point 101.3KPa(℃)-95.0
Liquid density 30℃(kg/㎥)1,050
Critical temperature(℃)82.0
Critical pressure(MPa)4.30
ODP0
GWP2,265 (AR4) / 2,060 (AR5)

Quality index

Purity≥99.9%
Water content≤0.001%
Acidity≤0.00001%
Evaporation residue≤0.01%
Chloride content-
Appearancecolorless and clear
Odorodorless

Applications

R22 retrofits in residential and commercial direct-expansion air conditioning, medium and low temperature refrigeration, and packaged equipment where the lubricant type on the nameplate is unclear. Suitable for supermarket systems and cold rooms in service and retrofit.

Packing options

  • Can: -
  • Disposable cylinder: 13.6kg(30Lbs) / 22.7kg(50Lbs)
  • Refillable cylinder: 50kg / 100kg / 800kg
  • ISO-TANK: 926L / 20ft ISO

Advantages & limitations

  • Works with mineral oil, alkylbenzene and POE, so an unknown lubricant history is not a blocker
  • Operating pressures closest to R22 among the HFC retrofit blends, simplifying safety settings
  • ASHRAE A1 and zero ODP, with no flammable-refrigerant charge limits to apply
  • The hydrocarbon fraction improves oil return in long suction lines and low-temperature circuits
  • Glide around 5.3 K, so liquid charging and a TXV re-trim are still required
  • GWP 2,265 above R22: no climate gain, only a compliance bridge
  • Capacity 5-10% below R22, most noticeable at low evaporating temperature
  • Not permitted in new cold storage warehouses under US SNAP since 2023

Replacements

Replaces: R22 across mineral-oil, alkylbenzene and POE systems, including R407C systems with poor oil return

Replaced by: R454C or R455A in new A2L equipment, and R448A/R449A where the system is already on POE

Regulations & phase-out

R438A is the broadest-spectrum R22 replacement still in volume, and its regulation follows the R22 phase-out rather than the HFC quota alone. Because it contains R125, R32 and R134a it is a controlled HFC at 2,265 CO₂ equivalent per kilogramme; US SNAP has already removed it from new cold storage, leaving service and retrofit as its remaining market.

  • 2010Chemours launches Freon MO99 (R438A) as a mineral-oil-compatible R22 retrofit.
  • 2015The HFC quota under Regulation 517/2014 starts charging R438A at 2,265 CO₂ equivalent per kilogramme.
  • 2020US EPA ends R22 production and import; reclaimed R22 only, which pushes service demand to R438A.
  • 2023EPA SNAP makes R438A unacceptable in new cold storage warehouses from 1 January.
  • 2024China completes its HCFC freeze and begins HFC quota enforcement, tightening R438A availability and price.

Sources: Chemours Freon MO99 product data; Regulation (EU) 517/2014 and 2024/573; US EPA SNAP rule and R22 phase-out; China MEE HCFC/HFC quota notices.

Need R438A price and MOQ?

Tell us your destination port and quantity — we reply within 12 hours.