R407A refrigerant gas cylinder supplied by SLIHE CHEMICAL

R407A Refrigerant Gas

HFC blend · R-407A ASHRAE A1 ODP 0 GWP 2,107 Purity ≥99.9%

R407A is the established European answer to R404A in medium-temperature display cases and cold rooms: same 20/40/40 family as R407C, but weighted towards R125 so that capacity stays close to R404A at low evaporating temperatures. GWP falls from 3,943 to 2,107, a 46% cut, and the retrofit keeps the existing copper, TXV body and POE charge in most cases.

Physical properties

Chemical nameR-407A
CompositionR-32 20 / R-125 40 / R-134a 40 (% mass, zeotropic)
Molecular formulaR-32 / R-125 / R-134a
Molecular weight90.0
Boiling point 101.3KPa(℃)-45.8
Freezing point 101.3KPa(℃)-95.0
Liquid density 30℃(kg/㎥)1,075
Critical temperature(℃)82.0
Critical pressure(MPa)4.51
ODP0
GWP2,107 (AR4) / 1,923 (AR5)

Quality index

Purity≥99.9%
Water content≤0.001%
Acidity≤0.00001%
Evaporation residue≤0.01%
Chloride content-
Appearancecolorless and clear
Odorodorless

Applications

Medium and low temperature commercial refrigeration: supermarket multi-deck cases, walk-in cold rooms, blast chillers and food processing. A direct retrofit for R404A and R502 systems that already run POE, and a capacity-matched alternative where R407C runs out of capacity at -25 °C.

Packing options

  • Can: -
  • Disposable cylinder: 13.6kg(30Lbs) / 22.7kg(50Lbs)
  • Refillable cylinder: 50kg / 100kg / 400kg / 800kg
  • ISO-TANK: 926L / 20ft ISO

Advantages & limitations

  • GWP 2,107 against 3,943 for R404A: a 46% cut without changing the compressor envelope
  • Capacity and pressure close to R404A at medium temperature, so shop fittings and line sizes stay
  • ASHRAE A1 non-flammable, unlike the A2L blends now being pushed into supermarkets
  • Works with the POE oil already in a converted R404A system
  • Zeotropic with 4-6 K glide: must be charged as liquid and the TXV setting has to be re-trimmed
  • Capacity is 3-8% below R404A at low temperature, which shows up on the coldest case
  • GWP still above the 1,500 line that several EU and US rules now use as a threshold
  • Not a drop-in for mineral-oil R22 systems: the oil has to be changed to POE

Replacements

Replaces: R404A and R502 in medium and low temperature commercial refrigeration; R22 in systems already converted to POE

Replaced by: R448A, R449A or R407F where a lower GWP or better efficiency is wanted; R454C/R455A where A2L is accepted

Regulations & phase-out

R407A is an HFC blend, so it lives inside the HFC quota and every kilogramme is charged at 2,107 CO₂ equivalent. It sits in an awkward band: low enough to beat R404A on quota cost, high enough that the 2025 European and American equipment thresholds exclude it from new installations. That is why it is now a retrofit product rather than a new-build choice.

  • 2015EU F-gas Regulation 517/2014 bans R404A in new equipment; R407A becomes the standard retrofit for existing cases.
  • 2020The EU service ban on virgin R404A above 2,500 GWP takes effect, pushing retrofits towards R407A and R448A.
  • 2022EU rules require new hermetically sealed commercial refrigerators to stay below GWP 150, closing the new-build door.
  • 2025US EPA Technology Transitions rule sets GWP limits for new supermarket systems; R407A qualifies only for retrofit and service.

Sources: Regulation (EU) 517/2014 and 2024/573; US EPA, Technology Transitions rule (40 CFR 84); IPCC AR4/AR5 GWP100 values; ASHRAE Standard 34.