R407A Refrigerant Gas
R407A is the established European answer to R404A in medium-temperature display cases and cold rooms: same 20/40/40 family as R407C, but weighted towards R125 so that capacity stays close to R404A at low evaporating temperatures. GWP falls from 3,943 to 2,107, a 46% cut, and the retrofit keeps the existing copper, TXV body and POE charge in most cases.
Physical properties
| Chemical name | R-407A |
| Composition | R-32 20 / R-125 40 / R-134a 40 (% mass, zeotropic) |
| Molecular formula | R-32 / R-125 / R-134a |
| Molecular weight | 90.0 |
| Boiling point 101.3KPa(℃) | -45.8 |
| Freezing point 101.3KPa(℃) | -95.0 |
| Liquid density 30℃(kg/㎥) | 1,075 |
| Critical temperature(℃) | 82.0 |
| Critical pressure(MPa) | 4.51 |
| ODP | 0 |
| GWP | 2,107 (AR4) / 1,923 (AR5) |
Quality index
| Purity | ≥99.9% |
| Water content | ≤0.001% |
| Acidity | ≤0.00001% |
| Evaporation residue | ≤0.01% |
| Chloride content | - |
| Appearance | colorless and clear |
| Odor | odorless |
Applications
Medium and low temperature commercial refrigeration: supermarket multi-deck cases, walk-in cold rooms, blast chillers and food processing. A direct retrofit for R404A and R502 systems that already run POE, and a capacity-matched alternative where R407C runs out of capacity at -25 °C.
Packing options
- Can: -
- Disposable cylinder: 13.6kg(30Lbs) / 22.7kg(50Lbs)
- Refillable cylinder: 50kg / 100kg / 400kg / 800kg
- ISO-TANK: 926L / 20ft ISO
Advantages & limitations
- GWP 2,107 against 3,943 for R404A: a 46% cut without changing the compressor envelope
- Capacity and pressure close to R404A at medium temperature, so shop fittings and line sizes stay
- ASHRAE A1 non-flammable, unlike the A2L blends now being pushed into supermarkets
- Works with the POE oil already in a converted R404A system
- Zeotropic with 4-6 K glide: must be charged as liquid and the TXV setting has to be re-trimmed
- Capacity is 3-8% below R404A at low temperature, which shows up on the coldest case
- GWP still above the 1,500 line that several EU and US rules now use as a threshold
- Not a drop-in for mineral-oil R22 systems: the oil has to be changed to POE
Replacements
Replaces: R404A and R502 in medium and low temperature commercial refrigeration; R22 in systems already converted to POE
Replaced by: R448A, R449A or R407F where a lower GWP or better efficiency is wanted; R454C/R455A where A2L is accepted
Regulations & phase-out
R407A is an HFC blend, so it lives inside the HFC quota and every kilogramme is charged at 2,107 CO₂ equivalent. It sits in an awkward band: low enough to beat R404A on quota cost, high enough that the 2025 European and American equipment thresholds exclude it from new installations. That is why it is now a retrofit product rather than a new-build choice.
- 2015EU F-gas Regulation 517/2014 bans R404A in new equipment; R407A becomes the standard retrofit for existing cases.
- 2020The EU service ban on virgin R404A above 2,500 GWP takes effect, pushing retrofits towards R407A and R448A.
- 2022EU rules require new hermetically sealed commercial refrigerators to stay below GWP 150, closing the new-build door.
- 2025US EPA Technology Transitions rule sets GWP limits for new supermarket systems; R407A qualifies only for retrofit and service.
Sources: Regulation (EU) 517/2014 and 2024/573; US EPA, Technology Transitions rule (40 CFR 84); IPCC AR4/AR5 GWP100 values; ASHRAE Standard 34.