Importing refrigerant gas from China looks simple on a price sheet and gets complicated at the port. The gas itself is cheap to make and easy to buy — what separates a smooth shipment from a seized one is paperwork: the right customs code, a dangerous-goods declaration the carrier accepts, a supplier who actually holds the export quota he is selling against, and an importer who has secured the destination-country allowance before the vessel sails. Those rules have hardened every year since 2021, and 2027 raises the bar again: the EU's HFC quota pool is cut in half, equipment bans land on chillers and monobloc units, and India closes its window for new HFC capacity licensing.
This guide walks through the whole chain in the order the work actually happens — classification, dangerous-goods shipping, certificates, the Chinese export side, and destination-country quota — with the codes, numbers and dates buyers need for 2027 planning. Where practice differs between carriers and customs offices, we say so explicitly instead of pretending there is one answer.
What changes in 2027
Four developments make 2027 a different market from 2026:
- The EU quota pool halves. Under Regulation (EU) 2024/573, the maximum HFC quantity that may be placed on the EU market falls from 42,874,410 t CO₂e per year (2025–2026) to 21,665,691 t CO₂e per year for 2027–2029 — from roughly 24% to 12% of the 2015 baseline. Bulk prices in Europe already reflect scarcity; the January 2027 step makes forward planning a purchasing function, not a sales function.
- EU equipment bans bite. From 1 January 2027, chillers up to 12 kW with GWP ≥ 150, chillers above 12 kW with GWP ≥ 750, and monobloc heat pumps and air conditioners up to 12 kW with GWP ≥ 150 may no longer be placed on the EU market — on top of the 2025 ban on small split air conditioners with GWP ≥ 750 and the 2026 ban on domestic refrigerators and self-contained refrigeration equipment.
- India closes its capacity window. India freezes HFC consumption in 2028 (Kigali Group 2) and will not issue environmental clearances for new or expanded HFC production capacity for controlled uses after 31 December 2027. Its import policy is already "Restricted": every HFC shipment needs a DGFT import authorisation backed by an Ozone Cell (MoEF&CC) recommendation.
- GCC approaches its freeze. Saudi Arabia, the UAE and the other Gulf states (Kigali Group 2) freeze HFC consumption in 2028, and Saudi Arabia's new import-licensing regime (Ministerial Decision No. 70, in force 1 November 2026) returns unlicensed refrigerant shipments at the importer's cost.
The United States, meanwhile, stays flat: the AIM Act step-down holds consumption at 60% of baseline for the whole of 2024–2028, so there is no US quota shock in 2027 — but the equipment-side GWP limits continue to roll in (VRF and computer-room air conditioning from 1 January 2027), and allowances still expire every 31 December with no carry-over.
Step 1 — Classify the gas correctly (HS codes)
Customs classification is where shipments are delayed, because refrigerants sit in three different chapters depending on what they are, and the Harmonized System itself changed at HS 2022. Many older checklists still point at the wrong subheadings.
What HS 2022 changed
Before 2022, nearly every fluorinated refrigerant — HFC included — crowded into subheading 2903.39 (or, for blends, Chapter 38). HS 2022 rebuilt the whole area:
- HCFCs and CFCs kept the 2903.7x range. HCFC-22 (R22) now has its own subheading, 2903.71 (China 10-digit: 2903710000), alongside 2903.72 (HCFC-123), 2903.73 (HCFC-141b), 2903.74 (HCFC-142b), 2903.75 (HCFC-225) and 2903.76 (halons). 2903.77–2903.79 catch the remaining CFCs and other HCFCs. These are phase-out chemicals — trade is licence-controlled in both directions.
- HFCs moved to a new 2903.4x range. HFC-23 (2903.41), HFC-32/R32 (2903.42), HFC-125 and HFC-143a (2903.44), HFC-134a (2903.45), HFC-227ea and other HFC propanes (2903.46), and further 2903.47–2903.49 for the longer-chain HFCs. In the Chinese tariff, R32 is 2903420000, R125 is 2903440020, R143a is 2903440010 and R134a is 2903450000 — every one of them named individually in China's export licence catalogue.
- HFOs got 2903.51/2903.59. HFO-1234yf, HFO-1234ze and HFO-1336mzz sit in 2903.51; other unsaturated fluorinated derivatives in 2903.59.
Blends live in heading 3827 — and the subheading depends on composition
Mixed refrigerants are not classified in Chapter 29 at all. Heading 3827 covers mixtures of halogenated derivatives of methane, ethane and propane, and its HFC subheadings are keyed to mass percentages of specific components. This is why a blend's HS code cannot be quoted from a product name alone — the assay decides it:
| Refrigerant | Composition (wt.%) | HS 6-digit | China 10-digit | Why |
|---|---|---|---|---|
| R410A | R32/R125 = 50/50 | 3827.63 | 3827630000 | ≥ 40% HFC-125 (and the 50:50 R125/R32 pair is named in the Chinese tariff) |
| R407C | R32/R125/R134a = 23/25/52 | 3827.64 | 3827640000 | ≥ 30% HFC-134a, no HFO |
| R404A | R125/R143a/R134a = 44/52/4 | 3827.61 | 3827610000 | ≥ 15% HFC-143a |
| R507A | R125/R143a = 50/50 | 3827.61 | 3827610000 | ≥ 15% HFC-143a |
| R448A / R449A / R452A | HFC + HFO blends | 3827.69 | 3827690000 | contains unsaturated fluorinated derivatives (HFOs) |
| HCFC blends (e.g. R406A) | — | 3827.31/32/39 | 3827320000 etc. | contains HCFCs, no CFCs |
Two practical consequences. First, a supplier reformulating a blend by even a few percentage points can move the goods to a different subheading — always classify against the batch certificate of analysis, not the datasheet from last year. Second, customs officers know these thresholds: the declaration elements for 3827 codes in China require the composition by weight, and declarations that quote a blend name without percentages invite inspection.
Natural refrigerants do not follow the fluorinated logic
| Refrigerant | Chemical | HS | China 10-digit | Note |
|---|---|---|---|---|
| R290 | propane | 2711.12 | 2711120000 | Chapter 27, not 29 — liquefied propane; 0% export rebate (vs 13% for fluorinated gases); export commodity inspection applies |
| R600a | isobutane | 2901.10 | 2901100000* | *practise varies (2901109000 also seen); commercial butane is 2711.13 — confirm with a pre-classification ruling |
| R717 | ammonia, anhydrous | 2814.10 | 2814100000 | hazardous chemical; inspection applies |
| R744 | carbon dioxide | 2811.21 | 2811210000 | statutory export inspection (monitoring conditions A/B); dry ice is UN 1845, class 9 — a different code and class |
The R290 case is the classic trap: buyers who assume "refrigerant, therefore Chapter 29" misdeclare propane, and the error changes the duty treatment and the export rebate arithmetic — fluorinated gases carry a 13% export VAT rebate, while liquefied propane carries none. Get the classification in writing before you compare FOB prices across gases.
Step 2 — Dangerous-goods shipping: every refrigerant is Class 2
All refrigerant gases are dangerous goods under the IMDG Code (sea), ADR (road) and IATA DGR (air): Class 2, gases, divided into 2.1 flammable, 2.2 non-flammable non-toxic and 2.3 toxic. The UN number and division drive everything: which cylinder certificate is acceptable, which carrier will take the booking, which port pair allows the transit, and what the transport document must say.
| Refrigerant | UN no. | Proper shipping name | Class / division |
|---|---|---|---|
| R22 | UN 1018 | chlorodifluoromethane (refrigerant gas R 22) | 2.2 |
| R32 | UN 3252 | difluoromethane (refrigerant gas R 32) | 2.1 — flammable |
| R125 | UN 3220 | pentafluoroethane (refrigerant gas R 125) | 2.2 |
| R134a | UN 3159 | 1,1,1,2-tetrafluoroethane (refrigerant gas R 134a) | 2.2 |
| R404A | UN 3337 | refrigerant gas R 404A | 2.2 |
| R407C | UN 3340 | refrigerant gas R 407C | 2.2 |
| R410A | UN 3163 or UN 1078 | liquefied gas, n.o.s. / refrigerant gas, n.o.s. | 2.2 |
| R507A | UN 1078 | refrigerant gas, n.o.s. (R 507A) | 2.2 |
| R1234yf | UN 3161 | liquefied gas, flammable, n.o.s. | 2.1 — flammable (A2L) |
| R448A / R449A / R452A | UN 1078 | refrigerant gas, n.o.s. | 2.2 |
| R452B / R454B | UN 1078 (confirm entry per carrier) | refrigerant gas, n.o.s. | 2.1 — A2L blends |
| R290 | UN 1978 | propane | 2.1 — flammable |
| R600a | UN 1969 | isobutane | 2.1 — flammable |
| R717 | UN 1005 | ammonia, anhydrous | 2.3 — toxic (subsidiary risk 8, corrosive) |
| R744 | UN 1013 | carbon dioxide | 2.2 |
Two entries deserve a second look. R410A has no dedicated UN number: some producers ship it as UN 3163 (liquefied gas, n.o.s.), while China's transport authorities list it under UN 1078 (refrigerant gas, n.o.s.) — carriers may accept either, but the entry on the dangerous-goods declaration, the MSDS and the cylinder marking must agree, so confirm the entry with your carrier before booking. A2L blends (R452B, R454B, R1234yf) are mildly flammable and move as Class 2.1, which narrows the carrier pool and forbids stowage next to certain cargo — expect a surcharge and a longer booking lead time.
Cylinders: the packaging is regulated too
Class 2 liquefied gases travel in pressure receptacles, and the cylinder itself must carry a valid inspection mark that the destination country recognises:
- Refillable cylinders: ISO 9809-1 / 9809-2 seamless steel with a periodic re-inspection still valid; DOT-3AA for US-domestic use. In the EU, transportable pressure receptacles must be TPED-approved (pi-marked, Directive 2014/68/EU).
- Non-refillable (disposable) cylinders: DOT-39 for the US market; in China, welded non-refillable cylinders are built to GB/T 17268 under the national cylinder safety code TSG R0006. Note that the EU now bans the import of non-refillable refrigerant cylinders altogether (Regulation 2024/573) — plan refillable or bulk packaging for European destinations.
- Ton tanks (drums) and ISO tanks: for volumes above a few tonnes, mobile ton tanks (roughly 800–1,000 kg net) or ISO tank containers (up to about 20 t) are the economic units, and most 2.2 refrigerants move this way for industrial buyers.
Every package must meet the IMDG packing instruction P200 for its UN number, with valve protection caps fitted and fill ratios respected. The shipping marks must show the UN number and proper shipping name exactly as they appear on the dangerous-goods declaration — mismatches between cylinder label, MSDS and DGD are the most common reason a container is held at the load port.
Documents and booking mechanics
- MSDS/SDS (16 sections, GHS-aligned). Section 14 must carry the UN number, proper shipping name, class, packing group (not applicable to Class 2) and marine pollutant status.
- Dangerous Goods Declaration (IMDG DGD) with the correct PSN, UN number, class, emergency contact and container-packing certificate.
- Package certification: cylinder specification certificates (GB/T, ISO, DOT, TPED as applicable) or, for cylinders packed in cartons, the exit dangerous-goods packaging certificate issued by Chinese inspection authorities.
- DG booking with the carrier, in advance. Carriers review Class 2 bookings individually; 2.1 and 2.3 cargoes need more approvals and have fewer port pairs. Book early, especially before Chinese New Year and ahead of summer peak season, when some European and Middle-East ports apply seasonal restrictions on flammable gases.
- Air freight is rarely practical. Under IATA rules most liquefied refrigerant gases are cargo-aircraft-only with strict quantity limits per cylinder; sea freight is the norm for everything above sample quantities.
Step 3 — Certificates and quality documents
Refrigerant is a commodity chemical: nobody audits your compressor, but everyone audits your file. Assemble the set before the goods ship, because several of these documents feed each other (the customs declaration quotes the COA assay; the DG declaration quotes the MSDS):
| Document | Issued by | What it must show |
|---|---|---|
| Certificate of Analysis (COA) | manufacturer, per batch | purity (typically ≥ 99.5%–99.9% depending on grade), moisture, acidity, non-condensables, and — for blends — the component assay that supports the HS code |
| Safety Data Sheet | manufacturer | 16 sections per GHS; Section 14 identical to the DGD |
| Quality-management certificate | certification body | ISO 9001 at minimum; ISO 14001 / ISO 45001 increasingly requested in tenders |
| Cylinder certificates | cylinder maker / inspection body | specification standard, test pressure, serial numbers, next inspection date |
| Export licence evidence | Chinese authorities | proof the supplier holds the HFC/HCFC export approval for that gas and year (see Step 4) |
| Destination-specific permits | importer | EU F-gas Portal registration; US EPA allowance; India Ozone Cell + DGFT authorisation; national licences per market (Step 5) |
| Certificate of Origin | CCPIT / customs | preferential origin where an FTA applies (ASEAN, GCC, Africa, RCEP partners) |
| REACH registration number | importer / only representative | for EU/UK imports above 1 t per year per substance — a registration, not a certificate from the factory |
One subtlety worth flagging for EU buyers: since 2025, imports of R32, R404A and R407C (and blends containing them) must be accompanied by a declaration of conformity and traceability documents showing that HFC-23 generated during production was properly destroyed. Ask your supplier to state this in writing on the batch documents; customs in several member states now check it.
Step 4 — The China export side: quota, licence, inspection
Buyers sometimes assume that the exporting country's paperwork is the supplier's problem. It is — until the supplier turns out not to have it, and the container is stuck at the port with your deposit inside. Here is what a compliant Chinese shipment rests on:
- HFCs have been licence-controlled since 1 November 2021. Every export of an HFC needs approval from China's national import/export management office for ozone-depleting substances (operated with MEE), after which the exporter obtains an export licence from MOFCOM. Quotas are allocated to licensed producers annually under China's Kigali obligations — a trading company without its own allocation must be exporting through a quota-holding producer.
- R22 is controlled even harder. As an HCFC, R22 export requires a licence under the ODS regime with annual quota limits, and enforcement is real: Chinese courts have convicted smugglers for exporting undeclared R22 under false HS codes. If a quotation for R22 arrives without licence paperwork, walk away.
- Statutory inspection (法检) applies to specific codes. R290 (2711120000) and R744 (2811210000) among others are subject to export commodity inspection; the inspection certificate is part of the export file. Fluorinated HFC codes generally carry a 13% export VAT rebate — part of why Chinese FOB prices are competitive — while propane carries 0%.
- Buyer-side due diligence: before paying a deposit, ask for (a) the supplier's export licence for the specific gas and year, (b) the quota-holding producer's name if the exporter is a trader, (c) a sample COA, and (d) the draft DG documents. A professional exporter produces these in a day. The money you save by skipping this check is a fraction of what a seized container costs.
Step 5 — Destination-country quota: the part that is now your job
The single biggest change of the past three years is that import control has moved from "do you have a licence" to "do you have quota measured in CO₂-equivalent tonnes". Two regimes dominate.
European Union: Regulation (EU) 2024/573
- Registration is the import licence. Valid registration in the EU F-gas Portal authorises import for all customs procedures except temporary storage. Customs declarations must state net mass, the CO₂e quantity (TCE) and the Portal registration number, and customs checks quota coverage in real time — goods without sufficient quota are not released.
- Bulk HFC needs quota above 10 t CO₂e/year. Quota is allocated annually from reference values; from 2025 (for 2026 quota onwards) it is no longer free — €3 per tonne CO₂e, payable by euro bank transfer only. Quota not paid for by the deadline is not allocated (and from 2028 is cancelled outright).
- The 2027 cap is 21,665,691 t CO₂e (2027–2029), half of the 2025–2026 level. New quota applications for the reserve open on 1 April 2027 for 2028–2030 and require three consecutive years of trade or RACHP activity — meaning buyers who want their own quota for 2028 must already be reporting today.
- Reporting and verification: annual report by 31 March; independent verification by a Portal-registered auditor by 30 April for imports of 1,000 t CO₂e or more (including pre-charged equipment).
- Equipment is a parallel rulebook. Pre-charged equipment above the 10 t CO₂e threshold needs quota authorisation from a quota holder; the Annex IV placing-on-market bans apply on their own schedule (2025 small splits, 2026 domestic refrigeration, 2027 chillers and monoblocs, as above). Having gas quota does not legalise a banned piece of equipment, and vice versa.
- Penalties: exceeding quota means a cut the following year plus administrative fines — at least five times the goods' market value under member-state law, and at least eight times for repeat offences within five years.
United States: AIM Act
- Bulk HFC import consumes allowances from EPA, weighted by exchange value. The step-down is 90% (2022–23), 60% (2024–2028), 30% (2029–2033), 20% (2034–35), 15% (2036+). There is no 2027 cut — but allowances expire each 31 December, cannot be carried over, and the next year's allocation is published around 1 October.
- Equipment imports do not consume allowances but must meet the Technology Transitions GWP limits: residential and light-commercial air conditioners and heat pumps at GWP ≤ 700 from 1 January 2025; VRF and computer-room AC at 1 January 2027.
- Transfers of allowances are discounted (5% for general allowances), and violations carry civil penalties in the six-figure range per violation per day under Clean Air Act enforcement.
For both regimes the planning consequence is the same: quota is a CO₂e budget, so gas choice is a compliance decision. A kilogram of R404A consumes roughly three times the quota weight of a kilogram of R448A. In 2027, buying high-GWP gas into the EU is not just expensive — it may be arithmetically impossible for the buyer's allowance pool.
Other markets at a glance
| Market | What the importer needs (2026–2027) |
|---|---|
| India | HFC import is "Restricted": DGFT import authorisation + Ozone Cell (MoEF&CC) recommendation; Ozone Cell registration mandatory; some 3827 codes limited to actual users (no trader imports); origin country must be a Montreal Protocol party. Freeze 2028, −10% in 2032. |
| Saudi Arabia | NCEC environmental clearance per shipment, linked to customs; new import-licence guide in force 1 Nov 2026 — unlicensed cargo returned at importer's cost. Kigali freeze 2028. |
| UAE | MOCCAE licence for import, export, re-export and transit of HFCs — including free zones; quarterly reporting. |
| Kuwait | R22 air-conditioner imports banned since Feb 2026 (parts: 10-year transition). |
| Kenya | NEMA licence for importers and RAC service companies; HCFC (incl. R22) imports banned from 1 Jan 2026; formal HFC permit system rolling out. |
| South Africa | DFFE (national ozone unit) permits; HFC quota under Climate Change Act 2024, first cut 2026; R22 import quota down to ~2.5% of former consumption. |
| Nigeria | NESREA clearance via the NesCAP portal (48-hour target) + SONCAP product conformity. |
| Egypt | EEAA ODS/HFC import licence; GOEIC registration with pre-shipment inspection and conformity certificate; ACID pre-declaration must match invoice and B/L. |
| Thailand | DIW hazardous-substance import licence with annual quantity allocation (2026 list: 65 HFC licensees). |
| Indonesia | Environment Ministry Reg. 25/2025 + Trade Ministry Reg. 20/2025: API-U/API-P registration, SINSW licensing, surveyor report; licences apply even inside free-trade zones. |
| Vietnam | Import quotas declining; from 2029 ≤ 90% of baseline, 2035 ≤ 70%, 2045 ≤ 20%; equipment users must register and report. |
| Malaysia | HFCs require a MITI import (and export) permit under the Customs Prohibition Order. |
The 2027 compliance calendar
| Date | What happens |
|---|---|
| 1 Jan 2027 | EU HFC quota cap halves to 21,665,691 t CO₂e; EU chiller and monobloc bans (GWP thresholds) take effect; US VRF/CRAC GWP limits apply. |
| 31 Mar 2027 | EU annual F-gas reports due (and nil-reports for quota holders who placed nothing). |
| 1 Apr 2027 | EU quota reserve declaration window opens (for 2028–2030 quota). |
| 30 Apr 2027 | EU independent verification due for ≥ 1,000 t CO₂e imports. |
| 1 Oct 2027 | EPA publishes 2028 allowances; US 2027 allowances expire 31 Dec. |
| 31 Oct 2027 | Typical deadline for next-year quota applications on the China side; India's 2028 quota cycle closes around the same window. |
| 31 Dec 2027 | Last day India grants environmental clearances for new/expanded HFC capacity for controlled uses. |
Ten mistakes that cost real money
- Classifying a blend by name instead of by assay. 3827 subheadings key off mass percentages; a rebalanced blend is a different code.
- Wrong or inconsistent UN entry. Cylinder label, MSDS and DGD must agree (and R410A has two accepted entries — pick one with your carrier).
- Buying from an exporter with no quota or licence. The goods stop at the Chinese port; deposits rarely come back fast.
- Assuming the EU quota problem is the seller's. Customs releases nothing without the importer's Portal registration and quota coverage in the buyer's own name.
- Ignoring the CO₂e arithmetic. Quota budgets are tonne-CO₂e, not kilograms — high-GWP purchases eat allowance at 3–4× the rate of low-GWP alternatives.
- Planning disposable cylinders into the EU. Non-refillable cylinder imports are banned there; budget refillable or ton-tank packaging.
- Underestimating DG lead time. Class 2 bookings, and especially 2.1/2.3 cargoes, need carrier approval and port-pair checks; peak-season restrictions add weeks.
- Air freighting bulk gas. IATA quantity limits make it viable only for samples; budget sea freight from the start.
- Treating transit or free zones as a loophole. UAE free zones are under MOCCAE; Indonesian FTZs still require licences and inspection; India rejects non-party origin.
- Forgetting HFC-23 documentation. EU imports of R32, R404A and R407C need a conformity declaration with traceability — ask for it at contract stage, not at customs.
Questions buyers ask
Can I import a small quantity into the EU without quota?
Below 10 t CO₂e per year, bulk HFC imports are exempt from quota but still require F-gas Portal registration and reporting. Note the threshold is on your annual placing on the market, not per shipment — three small shipments can exceed it.
Does my Chinese supplier need a US EPA allowance?
No. Allowances are consumed by the US importer of record. The supplier needs the Chinese export licence; you need the EPA allowance, and you should verify your allowance balance before confirming any shipment against it.
Which Incoterm should I use for DG cargo?
FOB Chinese port remains the most common for experienced importers, because the DG booking is easier to control on the origin side where the cylinder certificates are issued. CIF is workable with a reputable forwarder — but whoever books must hold the DG paperwork, and under CIF that means trusting the seller's forwarder with compliance-critical documents.
How do I verify an exporter's licence?
Ask for the export licence or quota approval document naming the specific HS code, gas and quantity, and check that the exporter's customs registration matches the documents. For larger orders, a third-party inspection or a factory audit closes the loop. It is a one-day request; treat reluctance to provide it as the answer.
Is R22 still importable at all?
Only for permitted service uses, under strict licence on both sides — and several markets have banned R22 equipment imports outright (Kuwait) or banned R22 imports entirely (Kenya from 2026). Servicing demand still exists, which is exactly why illegal R22 trade persists; keep your paperwork airtight or move customers to retrofit blends.
What about A2L refrigerants like R454B?
They are Class 2.1 dangerous goods (flammable, though weakly), so expect fewer carrier options and DG surcharges, and confirm the UN entry with your forwarder. Regulatory quota treatment follows their HFC content — check the blend's CO₂e weight against your allowance.
Importing for 2027?
SLIHE manufactures refrigerants factory-direct in Zhejiang, China — single gases from R22 to R134a, blends from R410A to the low-GWP HFO mixtures — and ships worldwide in non-refillable and refillable cylinders, ton tanks and ISO tanks. Every shipment leaves with the licence, COA, SDS and DG paperwork matched to the destination's rules, and we quote the quota arithmetic alongside the price so you know what your allowance will consume before you commit.
Get a Quote
Related reading: R404A Replacement Guide · Market Reports & Guides